- 2 x 2,100 kW (2,814Hp) V12 Wärtsila Nohab turbo charged medium speed diesel
|
- Port: 13,662 / Stbd: 13,646 (19th March 2020)
|
- 2 x 2.379:1 Rencke Tacke reverse reduction gearboxes
- 2 x Rencke PTO SHI-200 intermediate gearboxes for shaft generators
|
- 2 x LIPS controllable pitch propellers (2,100mm ø)
|
- 2 x Tenfjord 3M 160 TS/GM 415 electro/hydraulic rotary vane steering gear with 2 x 380V AC, 3-phase 5.5kW steering gear pumps
- 2 x Semi balanced spade rudders
- Electronic rudder paralleling system
|
- 1 x Tenfjord for port rudder
- 1 x Anschütz for stbd rudder
- 3 x Repeaters on wing stations and in engine room
|
- 1 x 108hp (81kw) LIPS FT01 (380V AC, 3 phase), 605mm diameter
|
- Blohm & Voss AG-FK 21 Hydraulic pump 11kW Fin area 2.5m2
- Automatic low speed interlocking, interfaced to log
|
- 2 x 230kW / 270kVA MAN 2866
- Diesel; LE (with 2 x Stamford alternators MHC 484 E) producing 3 x 380V AC 3 phase, 50Hz
|
- Port Generator fitted with HUG catalytic exhaust cleaning system with bypass & selection through funnel or through hull on port side
- Starboard Generator exhaust through starboard hull side only
|
- 40 litres/ 10.5 US gallons p/h (when shaft generators not in use, with airconditioning running & normal deck work being carried out)
|
- Port: 17,040 / Stbd: 19,074 (19th March 2020)
|
- 1 x 59kW/69kVA Caterpillar 3304B
- 4 cylinder type 3304 producing 380V
- AC 3 phase 50Hz
|
- 2 x 230kW/270kVA (at 800 rpm)
- Stamford shaft generators type
- MHC434E, 3 phase, 410Amp 50Hz
|
- 380v AC, 3 phase, 50Hz
- 220v AC, single phase 50Hz
- 24v DC
|
- 380v AC, 3 phase 50Hz, (400Amp/hour)
|
- 24v DC battery banks for:
- GMDSS equipment
- Bridge equipment
- Bridge radio & communication equipment
- Emergency lighting
- Emergency generator starting
- Control room
|
- Carrier with 3 x Compressors type 5F60,
- Cooling capacity each unit 83kW
- Air intakes in cabins equipped w/heaters (total 78kW)
|
- 2 x Idromar (7.5kW, 380V, 3-phase) reverse osmosis MC9
- 9,600 litres (2,536 USG/ per unit per day
|
|
- Hamann Wassertechnik Capable of treating 4m3 / hour (USCG approved)
|
- Alfa Laval MIB330
- Racor fuel filter (3 x for each Main Engine,
- 2 x For each Auxiliary Engine/ 1 x on standby)
|
- NFV type PPT-BWS-500 15ppm (USCG/MARPOL approved)
|